Used Software:
DATAQ Instruments, Inc.
241 Springside Drive Akron, OH 44333
- WinDaq/HS High Speed Recording software Version 3.29
- WinDaq/XL WinDaq add-on that allows acquired data
to be ported to a Microsoft Excel spreadsheet
WinDaq Settings:
- Sample Rate: 960
- Active Chanels: 1,2,3,4,5,6
- Acquisition Method Chanel 1,2,5,6: RMS
- Acquisition method Chanel 3,4: Average
Windaq-XL Settings:
- Mode: Looping
- Time Stamp: Yes
- Starting Cell: A1
- Rows to Fill: 60
Microsoft Excel Settings:
Chanel 1 Power Shaft 1
A1:Volt A2-A61: Numeric Datas =AVERAGE(A2:A61) at I3 =PRODUCT(I3,100) at I4 Factor 100 to measure W as: Chanel 1 Power Shaft 1 Source Analog Output Chanel 1 ID#256191 Range Min -1000.0 W Range Max 1000.0 W Out Min -10.000 V Out Max 10.000 V ID#256191 (ComoTorque Type 4700) connected to ID#247687 (Torque Sensor)
Chanel 2 Power Shaft 2
B1:Volt B2-B61: Numeric Datas =AVERAGE(B2:B61) at K3 =PRODUCT(K3,100) at K4 Factor 100 to measure W as: Chanel 2 Power Shaft 2 Source Analog Output Chanel 1 ID#251546 Range Min -1000.0 W Range Max 1000.0 W Out Min -10.000 V Out Max 10.000 V ID#251546 (Como Torque Type 4700) connected to ID#251545 (Torque Sensor)
Chanel 3 Speed Shaft 1
C1:Volt C2-C61: Numeric Datas =AVERAGE(C2:C61) at I8 =PRODUCT(I8,100) at I9 Factor 100 to measure rpm as: Chanel 3 Speed Shaft 1 Source Analog Output Chanel 1 ID#256191 Range Min -1000.0 W Range Max 1000.0 W Out Min -10.000 V Out Max 10.000 V ID#256191 (ComoTorque Type 4700) connected to ID#247687 (Torque Sensor)
Chanel 4 Speed Shaft 2
D1:Volt D2-D61: Numeric Datas =AVERAGE(D2:D61) at K8 =PRODUCT(K8,100) at K9 Factor 100 to measure rpm as: Chanel 4 Speed Shaft 2 Source Analog Output Chanel 1 ID#251546 Range Min -1000.0 W Range Max 1000.0 W Out Min -10.000 V Out Max 10.000 V ID#251546 (ComoTorque Type 4700) connected to ID#251545 (Torque Sensor)
Chanel 5 Torque Shaft 1
E1:Volt E2-E61: Numeric Datas =AVERAGE(E2:E61) at I13 =PRODUCT(I13,20) at I14 Factor 20 to measure Nm as: Chanel 5 Torque Shaft 1 Source Analog Output Chanel 1 ID#256191 Range Min -100.0 W Range Max 100.0 W Out Min -5.000 V Out Max 5.000 V ID#256191 (ComoTorque Type 4700) connected to ID#247687 (Torque Sensor)
Chanel 6 Torque Shaft 2
F1:Volt F2-F61: Numeric Datas =AVERAGE(F2:F61) at K13 =PRODUCT(K14,20) at K14 Factor 20 to measure Nm as: Chanel 6 Torque Shaft 2 Source Analog Output Chanel 1 ID#251546 Range Min -100.0 W Range Max 100.0 W Out Min -5.000 V Out Max 5.000 V ID#251546 (ComoTorque Type 4700) connected to ID#251545 (Torque Sensor)
|